AE lo consumption increases after overhaul reasons?

Check all the valves of lo system are properly operated and holding, check dipstick bottom for blockage which can give nonferrous reading.Check operation of purifier. Check whether piston scraper ring is put correctly if put in upside down lot of oil will burn in the combustion space. Check whether the valve spindles are properly aligned which also can lead in lo burning in combustion chamber

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).