Checking- attach service air on top of the valve and check for a lift atleast 15-20mm. And on closing the air valves must be shut instantly.
Dismantling- shut air supply- attach two eyebolts and dismount by using a lifting wire after
unscrewing holding bolts. keep the starting air valve on vice with soft jaws. remove top cover. remove two bolts attaching the piston to the spindle. the piston will come out due to spring force. remove the valve and spindle through the bottom.lap valve lid and valve seat properly and mount back all parts.

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).