1. remove plug from inlet pipe and remove oil .
2.remove sealing water pipe, inlet and outlet pipes.
3.remove flow rate regulating orifice plate from the inlet side.
4. Remove cover-nut, nut tightening inlet pipe and socket set screw( holding inlet pipe from rotation).
5. slightly hammer on top of the inlet pipe to detach tightly held tapered portion.
6. remove sludge cover nuts(top cover) and remove sludge cover by mounting a jack for removing it.
7. Using disc nut handle remove disc nut and remove heavy liquid chamber,impeller and gravity disc n sealing ring)
8. Mount the light liquid chamber handle and remove light liquid chamber and impeller with inlet pipe.
9. Remove the capnut (tightening bowl on to the vertical shaft using cap-nut removing spanner(set the spanner on the cap nut and thread the threaded rod on to the top of cap-nut and remove).
10. Mount the jack on the threaded portion of the distributor , turn down the jack until the bowl is slightly raised.

11.mount shackle on jack and draw bowl vertically and keep it on the dismantling stand.
12. thread the disc clamp plate on to the distributor and tighten the nut and the bowl nut can be removed by using bowl nut handle.
13 keep the protective plate on top of the bowl hood and also place jack on bowl-hood and secure it with disc-nut, turn the push bolt to raise the bowl hood and remove it using chain block.
14. turn the bowl hood and remove the sealing ring using a screw driver.
15. mount the jack on the distributor and remove the disc stack.
16. install protective plate on top the portion of bowl where cap nut is holding and secure the jack by threading in four bolts on to the sliding bowl and remove it by threading down the push bolt and evenly hitting with a soft hammer.
17. remove  the pilot valves using special tool

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).

M/e trouble-what to check if Engine is not starting on air and fuel?

Engine not starting on Air: - * Low air bottle pressure or airline valve may be shut. * Air bottle isolating valve or automatic valve or distributor not functioning. * Control air valves faulty or less control air pressure. * Starting air automatic valve jammed. * Turning gear engaged. * Reversing has not taken place completely. * Control valve for fuel or start is not in its end position. * Bursting diaphragm(disc) on start airline damaged. * Fuel lever on maneuvering stand not on remote mode. * Auxiliary blower not running or not on ‘auto’ mode. * Emergency stop has activated. * Interlock is operated. *Cylinder air start valve defective or sticky. *Piston not in firing mode.   Engine not starting on fuel: - *Less fuel in service tank. * Fuel Oil filter is chocked. * Fuel Oil supply pumps not delivering required pressure. Or fuel pump tripped. * Puncture valve still active. *Fuel oil temperature to low. * Fuel level on local maneuvering stand, is not on remote stand. * Fuel rack...