Crankcase door not fitted in refrigeration compressor

To prevent contamination of refrigeration system by air and moisture as crankcase forms the suction chamber of the compressor, also there is no risk of crankcase explosion as no O2 will be available in the crankcase
and no possibility of hot spots as incoming refrigerant temperature is low.

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).