Interlocks and Blocking devices in main engine starting system

Interlocks or blocking devices are provided so that engine cannot be started until required conditions are fulfilled .
Turning gear interlock prevents engine starting while turning gear engaged.

Running dirction interlock prevents engine to be started in reverse direction until all cam rollers of fuel pump have shifted.
Telegraph position interlock allows engine to be started only in the direction intended by bridge. Distributor position interlock.checks whether distributor is whether in start or stop direction.it has to be in either in one direction to commence starting.

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).