M/e trouble-what to check if Engine is not starting on air and fuel?

Engine not starting on Air: -
* Low air bottle pressure or airline valve may be shut.
* Air bottle isolating valve or automatic valve or distributor not functioning.
* Control air valves faulty or less control air pressure.
* Starting air automatic valve jammed.
* Turning gear engaged.
* Reversing has not taken place completely.
* Control valve for fuel or start is not in its end position.
* Bursting diaphragm(disc) on start airline damaged.
* Fuel lever on maneuvering stand not on remote mode.
* Auxiliary blower not running or not on ‘auto’ mode.
* Emergency stop has activated.
* Interlock is operated.
*Cylinder air start valve defective or sticky.
*Piston not in firing mode. 
Engine not starting on fuel: -
*Less fuel in service tank.
* Fuel Oil filter is chocked.
* Fuel Oil supply pumps not delivering required pressure. Or fuel pump tripped.
* Puncture valve still active.
*Fuel oil temperature to low.
* Fuel level on local maneuvering stand, is not on remote stand.
* Fuel rack stuck.
* Fuel pump malfunctioning, jammed plunger.
* Injector nozzle needle sticking or holes blocked.
* Compression pressure is too low due to broken piston ring or exhaust valve not closing properly.
* Fuel pump relief valve leaking.
* Start air pressure insufficient to turn the engine fast enough.

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).

Hyper mist fire fighting system working

It will get activated only when two detectors are activated Once it is activated it will send a signal to a fire alarm panel from fire alarm panel sense the zone of fire and it will signal to the hyper mist control panel H.M control panel sends a signal to high-pressure pump (Plunger type reciprocating pump) starter and also solenoid operating valve according to the zone of fire Capacity of pump: 200 litres/min @ 70 bar pressure discharge At nozzle 12-20 litre/min @ 50 bar pressure discharge it is a very high water mist system which creates a water fog which effectively puts out the fire whole also providing a cooling effect the speciality of H.M Nozzle: its diffuser action in nozzle drop in pressure at nozzle throat will breaking the liquid particle into a fine mist