Skip to main content

Priming arrangements

Liquid ring air primer pump- it consists of a bladed circular rotor shrouded on the under side, which rotates in an oval casing, which has a supply of sealing water, water is thrown outside by the impeller which whirls
around in the casing,  the water seals and also recedes and approach rotor boss twice in each revolutions, which gives an effect of producing rotating water pistons between the blades.

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).