Testing of compressor pressure relif valves

The pressure relief valve acts as a backup safety device to the pressure switch. It is designed to automatically open when the pressure in the receiver reaches dangerous levels. The pressure relief valve is tested by running the air compressor with the pressure switch fully open. When the pressure switch is fully open it cannot shut down the compressor.
The pressure relief valve should open automatically when the pressure reaches 25 psi above the normal operating pressure. If the pressure relief valve does not open it may be defective. The valve may also be defective if it opens before the receiver reaches normal operating pressure. Defective relief valves must be replaced before the compressor is restarted

Comments

Popular posts from this blog

Why atomisation test should not be done in slide type fuel valves

Since very small needle lift is obtained in the test equipment result in an unequal pressure distribution in the cut off shaft resulting in a hard contact in a small area along with high frequency oscillations, low lubricity of test oil will increase the chance of seizure. Full lift and high lubricity of heavy oil eliminates this risk  of seizure during normal operation.( Always open and clean slide type valves before testing as cold sticky heavy oil along with small clearances can cause restriction in the movement of the spindle).